The operator shall select the test by entering the key panel part number from a configuration menu The monitor shall initially display set-up requirements: Tooling, Tooling Location on X-Y Table, Interface Cables and any special requirements The operator shall enter key panel serial number The system shall position, probe and test each key Measuring Force, Displacement, Contact Resistance. Speed Programmable
The system shall provide printed data if requested. All data to be stored on hard drive in specified files. Engineering data, in the form of force displacement curves, shall also be generated and accessible if requested.
The X-Y positioning shall be by teach method, coordinates are optional. Test Parameters, Contact Resistance Limits, Matrix Scheme, Force/Deflection and Tolerances, windows of limits shall be entered by way of menu screens.