921B Displacement Force Test Station Specifications & Features

| Power Requirements | 115/220 V ac, 50/60 Hz, 230 VA |
| Test Speed | As fast as 8 mm/s (0.32 inch/s); as slow as 0.0254 mm/s (0.001 inch/s) |
| Measurement Units | Metric or English - user selectable |
| Displacement* | |
|---|---|
| Range: | 0 to 62.51 mm (0 to 2.46 inches) programmable |
| Resolution: | 0.00254 mm (0.0001 inch) programmable |
| Abs Accuracy: | ±0.00762 mm (±0.0003 inch) max |
| Repeatability: | ±0.00762 mm (±0.0003 inch) max |
| Force* | |
|---|---|
| Range: | 0 to 3.60 kg (0 to 127 oz); other available ranges include 0-75.0 g 0-2.65 oz), 0-360 g (0-12.7 oz), 0-2.00 kg (0-70.6 oz) and 0-22.68 kg (0-50.0 lb) |
| Resolution: | 1 g (0.035 oz) |
| Abs Accuracy: | ±0.25% of full scale max |
| Repeatability: | ±0.1% of full scale max |
| Tested Parameters | ||
|---|---|---|
| Actuation: | Release: | Calculation: |
| FMAX = actuation force | FRESTORE = FMIN @ release | Tactile ratio = (FMAX - FMIN) / FMAX |
| FMIN = minimum force | TRESTORE = travel @ FRESTORE | |
| TMIN = travel @ FMIN | ||
| TMAX = travel @ FMAX |
*Options available
Options
Resistance/Voltage Channel(FDR Mode)
Resistance range of 0 - 16 kΩ or voltage range of 0 - 4 V; other resistance/voltage range available. Measures resistance for
tactile and non-tactile switches. Tests the following additional parameters:
FMAKE, FBREAK, FLOW, TMAKE, TBREAK, TLOW, RMAX, RMIN, RMAKE, RBREAK, RRESTORE, RLOW
- 42.5H x 45.7W x 45.7D cm
- (16¾H x 18W x 18D inches)
- 14.2 kg (31.5 lb)
- 42.5H x 30.5W x 30.5D cm
- (16¾H x 12W x 12D inches)
- 7.8 kg (17 lb)
| Test Configuration | Force Displacement Graph |
| Force Displacement Resistance Graph |
For inquires in Europe or South America please see contact information below. All other inquires contact TRICOR directly
.
- Europe
- Ian Ridpath
- Nicomatic (UK) LTD
- United Kingdom
- [44] (146) 267-7886
- Fax [44] (146) 267-7499
- ian.ridpath@nicomatic.co.uk
- South America
- Carlos Guimaraes
- Nicomatic South America
- Brazil
- [55] (11) 387-22791
- Fax [55] (11) 367-28830
- carlos.guimaraes@nicomatic.com.br
TD-590